xi | |
|
|
1 | (20) |
|
|
|
|
|
1.1 Current Methods of Physiological Monitoring |
|
|
2 | (1) |
|
1.2 Need for Noncontact Physiological Monitoring |
|
|
3 | (2) |
|
1.2.1 Patients with Compromised Skin |
|
|
3 | (1) |
|
|
4 | (1) |
|
|
5 | (1) |
|
1.3 Doppler Radar Potential for Physiological Monitoring |
|
|
5 | (16) |
|
1.3.1 Principle of Operation and Power Budget |
|
|
6 | (2) |
|
1.3.2 History of Doppler Radar in Physiological Monitoring |
|
|
8 | (8) |
|
|
16 | (5) |
|
|
21 | (18) |
|
|
|
|
2.1 Brief History of Radar |
|
|
21 | (1) |
|
2.2 Radar Principle of Operation |
|
|
22 | (6) |
|
2.2.1 Electromagnetic Wave Propagation and Reflection |
|
|
23 | (1) |
|
2.2.2 Radar Cross Section |
|
|
24 | (1) |
|
|
25 | (3) |
|
|
28 | (4) |
|
|
28 | (1) |
|
2.3.2 Doppler Radar Waveforms: CW, FMCW, Pulsed |
|
|
29 | (3) |
|
2.4 Monostatic and Bistatic Radar |
|
|
32 | (3) |
|
|
35 | (4) |
|
|
36 | (3) |
|
3 Physiological Motion and Measurement |
|
|
39 | (30) |
|
|
|
3.1 Respiratory System Motion |
|
|
39 | (5) |
|
3.1.1 Introduction to the Respiratory System |
|
|
39 | (1) |
|
|
40 | (3) |
|
3.1.3 Chest Wall Motion Associated with Breathing |
|
|
43 | (1) |
|
3.1.4 Breathing Patterns in Disease and Disorder |
|
|
43 | (1) |
|
|
44 | (9) |
|
3.2.1 Location and Gross Anatomy of the Heart |
|
|
45 | (1) |
|
3.2.2 Electrical and Mechanical Events of the Heart |
|
|
46 | (2) |
|
3.2.3 Chest Surface Motion Due to Heart Function |
|
|
48 | (2) |
|
3.2.4 Quantitative Measurement of Chest Wall Motion Due to Heartbeat |
|
|
50 | (3) |
|
3.3 Circulatory System Motion |
|
|
53 | (5) |
|
3.3.1 Location and Structure of the Major Arteries and Veins |
|
|
54 | (1) |
|
3.3.2 Blood Flow Through Arteries and Veins |
|
|
55 | (1) |
|
3.3.3 Surface Motion from Blood Flow |
|
|
56 | (1) |
|
3.3.4 Circulatory System Motion: Variation with Age |
|
|
57 | (1) |
|
3.4 Interaction of Respiratory, Heart, and Circulatory Motion at the Skin Surface |
|
|
58 | (1) |
|
3.5 Measurement of Heart and Respiratory Surface Motion |
|
|
58 | (11) |
|
3.5.1 Radar Measurement of Physiological Motion |
|
|
59 | (1) |
|
3.5.2 Surface Motion Measurement of Respiration Rate |
|
|
59 | (2) |
|
3.5.3 Surface Motion Measurement of Heart/Pulse Rate |
|
|
61 | (2) |
|
|
63 | (6) |
|
4 Physiological Doppler Radar Overview |
|
|
69 | (26) |
|
|
|
|
|
|
|
70 | (13) |
|
4.1.1 Quadrature Receiver |
|
|
73 | (4) |
|
4.1.2 Phase Coherence and Range Correlation |
|
|
77 | (2) |
|
|
79 | (1) |
|
4.1.4 Antenna Considerations |
|
|
80 | (1) |
|
|
80 | (3) |
|
|
83 | (3) |
|
4.2.1 Analog Signal Conditioning and Coupling Methods |
|
|
83 | (2) |
|
|
85 | (1) |
|
|
86 | (4) |
|
|
86 | (1) |
|
4.3.2 Demodulated Phase Processing |
|
|
87 | (3) |
|
|
90 | (2) |
|
|
90 | (2) |
|
|
92 | (1) |
|
|
92 | (3) |
|
|
93 | (2) |
|
5 CW Homodyne Transceiver Challenges |
|
|
95 | (42) |
|
|
|
|
|
|
|
|
|
95 | (18) |
|
5.1.1 Single-Channel Limitations |
|
|
96 | (7) |
|
5.1.2 LO Leakage Cancellation |
|
|
103 | (6) |
|
5.1.3 IQ Imbalance Assessment |
|
|
109 | (4) |
|
|
113 | (5) |
|
|
113 | (1) |
|
|
114 | (4) |
|
|
118 | (19) |
|
5.3.1 DC Offset and DC Information |
|
|
118 | (7) |
|
|
125 | (5) |
|
5.3.3 DC Cancellation Results |
|
|
130 | (4) |
|
|
134 | (3) |
|
6 Sources of Noise and Signal-to-Noise Ratio |
|
|
137 | (34) |
|
|
|
|
6.1 Signal Power, Radar Equation, and Radar Cross Section |
|
|
138 | (5) |
|
|
138 | (2) |
|
6.1.2 Radar Cross Section |
|
|
140 | (1) |
|
6.1.3 Reflection and Absorption |
|
|
141 | (1) |
|
6.1.4 Phase-to-Amplitude Conversion |
|
|
141 | (2) |
|
6.2 Oscillator Phase Noise, Range Correlation and Residual Phase Noise |
|
|
143 | (8) |
|
6.2.1 Oscillator Phase Noise |
|
|
143 | (4) |
|
6.2.2 Range Correlation and Residual Phase Noise |
|
|
147 | (4) |
|
6.3 Contributions of Various Noise Sources |
|
|
151 | (4) |
|
|
151 | (3) |
|
|
154 | (1) |
|
6.3.3 RF Additive White Gaussian Noise |
|
|
154 | (1) |
|
6.4 Signal-to-Noise Ratio |
|
|
155 | (2) |
|
6.5 Validation of Range Correlation |
|
|
157 | (1) |
|
6.6 Human Testing Validation |
|
|
158 | (13) |
|
|
168 | (3) |
|
7 Doppler Radar Physiological Assessments |
|
|
171 | (36) |
|
|
|
|
|
|
|
172 | (4) |
|
|
176 | (3) |
|
|
179 | (5) |
|
|
184 | (1) |
|
7.5 Heart Rate Variability |
|
|
185 | (5) |
|
7.6 Respiratory Sinus Arrhythmia |
|
|
190 | (6) |
|
7.7 RCs and Subject Orientation |
|
|
196 | (11) |
|
|
204 | (3) |
|
8 Advanced Performance Architectures |
|
|
207 | (62) |
|
|
|
|
|
|
|
|
|
8.1 DC Offset and Spectrum Folding |
|
|
208 | (16) |
|
8.1.1 Single-Channel Homodyne System with Phase Tuning |
|
|
208 | (5) |
|
8.1.2 Heterodyne System with Frequency Tuning |
|
|
213 | (7) |
|
8.1.3 Low-IF Architecture |
|
|
220 | (4) |
|
8.2 Motion Interference Suppression |
|
|
224 | (26) |
|
8.2.1 Interference Cancellation |
|
|
226 | (5) |
|
8.2.2 Bistatic Radar: Sensor Nodes |
|
|
231 | (9) |
|
|
240 | (10) |
|
|
250 | (19) |
|
8.3.1 Physiological Monitoring with FMCW Radar |
|
|
250 | (1) |
|
8.3.2 Physiological Monitoring with UWB Radar |
|
|
251 | (15) |
|
|
266 | (3) |
|
9 Applications and Future Research |
|
|
269 | (16) |
|
|
|
9.1 Commercial Development |
|
|
269 | (3) |
|
|
269 | (3) |
|
|
272 | (1) |
|
9.2 Recent Research Areas |
|
|
272 | (10) |
|
|
272 | (3) |
|
|
275 | (1) |
|
9.2.3 Multiple Subject Detection |
|
|
276 | (3) |
|
|
279 | (3) |
|
|
282 | (3) |
|
|
282 | (3) |
Index |
|
285 | |